What is Timescale in verilog codes

Posted by Nityanand Dubey on March 18, 2009

The ‘timescale is one of the compiler directive to specify the unit for the delays used in the design with their precision.

The timescale line is very important in the verilog simulation, because there are no any default delays specified by the verilog.

Syntax :

`timescale <time unit>/<time precision>

Here :

time unit : This is the time to be used as one unit for all the delays used in the design.

time precision : This represents the minimum delay which needs to be considered during simulation or it decides that how many decimal point would be used with the time unit.

Range of Timescale :

The range for time unit can be from seconds to femto-seconds, which includes all the time units including s (second), ms(mili-second), us(micro-second), ns(nano-second), ps(pico-second) and fs(femto-second).

Example :

`timescale 1ns/1ps

Here :

1ps = 0.001 ns

#1; // = 1ns delay

#1.003; // = will be considered as a valid delay

#1.0009; // = will be taken as 1 ns only since it is out of the precision value.

Advertisements

3 Responses to “What is Timescale in verilog codes”

  1. Отличный блог, интересное и полезное содержание!

    Great blog, interesting and useful content!

  2. Ravi Teja G said

    thanks

  3. arvinth said

    good example

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Google+ photo

You are commenting using your Google+ account. Log Out / Change )

Connecting to %s

 
%d bloggers like this: